User's Manual

Table Of Contents
Installation
BreezeMAX Wi² and BreezeACCESS Wi²
System Manual 31
2.3.7 Connecting the Grounding Cables
1 Connect a grounding cable to the grounding stud on theWi² unit and tighten
the grounding screw firmly.
2 Connect a grounding cable to the grounding stud on the SU-ODU and tighten
the grounding screw firmly.
3 Connect the other ends of the grounding cables to a good ground (earth)
connection.
2.3.8 Connecting to Power Source
1 Connect the power cable (see Section 2.3.4) to the power socket on the unit
and to the mains supply.
2 Check that the LED on the Wi² is green indicating that the system is working
normally.
To connect the grounding cables:
CAUTION
Be sure that grounding is available and that it meets local and national electrical codes. For
additional lightning protection, use lightning rods, lightning arrestors, or surge suppressors.
CAUTION
The Wi²
can be connected to either an AC or DC power source, or to both. By default the DC plug is
covered with a waterproof sealing cap which must be removed before connecting to the power
cable. Any socket that is NOT in use must always be protected from moisture and must be covered
with a waterproof sealing cap.