User's Manual

Table Of Contents
Installation
BreezeMAX Wi² and BreezeACCESS Wi²
System Manual 27
2.3.5 Pre-Configuration and Testing
It is highly recommended that you configure the parameters of the Access Point
(AP) unit and the SU-ODU and verify proper operation of the system in the
laboratory before installing the Wi² unit.
1 Set up the unit a short distance (4.5m to 7.5m) from an approved test unit,
either outdoors or indoors.
2 Connect the power cable to the power socket on the unit. Connect the other
end to the mains supply.
3 Check that the LED on the Wi² is green indicating that the system is working
normally.
4 Using Telnet, login as outlined in Chapter 3 - "Initial Configuration" and
complete the initial configuration.
5 Complete the configuration of the AP, using either Telnet or the web-based
interface as outlined in Chapter 4 - "System Configuration".
6 Disconnect the cable connecting the SU-ODU to the SU port of the Wi²unit.
7 Connect an SU-IDU to the SU-ODU.
8 Connect a PC to the Ethernet port of the IDU and configure its parameters. For
configuration details refer to the relevant manual.
9 After configuring the parameters of the AP and SU-ODU and verifying proper
operation of the system, disconnect the unit from the power source and
proceed to mount the unit as outlined in Section 2.3.6.
To configure the AP unit: