System information
Panel Display
3-5
Console Configuration
If you are having difficulties making an out-of-band console connection to the serial
port on the agent module, you can display or modify the current settings for the
serial port through the Web agent. Click on the management module icon in the
switch image to display or configure these settings, as shown below.
Parameter Default Description
Baud rate 19200 bps The rate at which data is sent between devices.
Options : 2400, 4800, 9600, 19200, and auto detection.
Note that when AUTO is selected, you need to first press the Enter
key once to set the data rate and initialize the connection.
Time-Out 10 minutes If no input is received from the attached device after this interval, the
current session is automatically closed.
Range : 0 - 100 minutes; 0: disabled
Data bits 8 bits Sets the data bits of the RS-232 port.
Options : 7, 8
Stop bits 1 bit Sets the stop bits of the RS-232 port.
Options : 1, 2
Parity none Sets the parity of the RS-232 port.
Options : none/odd/even
Auto-Refresh Time 5 seconds Sets the interval before a console session will auto refresh the
console information, such as Spanning Tree Information, Port
Configuration, Port Statistics, and RMON Statistics.
Range : 5-255 seconds; 0: disabled