Installation guide
The controller must be configured before it can be used. Configuration involves setting up devices such as moisture sensors, 
flow meters, zone adapters and water sources, and assigning these devices to zones.  
In order to properly configure the system, you must first configure the devices and then configure the zones by assigning the 
devices to zones. 
Controller Configuration 
Configuring the controller allows you to edit general controller settings. These include Central Controller Settings, modem 
settings, clock, etc...  
To configure the controller select “Configure>Controller Configuration…” from the file menu. 
Operational Settings Tab 
Max Zones Watering Simultaneously 
This field adjusts the number of zones that are allowed to water simultaneously. Although the maximum value is four, the 
actual number will depend on the individual flow rates of the zones, the water management settings, etc.  
Valve Delay/Flow Setting 
Most systems have a delay between the time the valve opens and the time water begins to flow. Use this setting to adjust 
the valve time delay from 1 to 999 seconds.  
Minutes between sensor log readings 
This field adjusts the time between moisture sensor log readings. It can be adjusted from 5 to 60 minutes.  
Factory Settings Tab 
Factory/Calibrations settings are displayed here. 
Factory settings should not be modified unless directed by an Acclima technician.   