Specifications

Strata CIX200
Modular or Amphenol Connections
24 Strata CIX General Description 08/14
LCNU-A1A, LCNU-B1A, LCNU-C1A, LCNU-D1A, LEXU, and LCNU-E1A
Table 8 CIX Extender Use
Extender Used For Required Comments
LEXU-A1A LIPU/MIPU Optional
Extender installed between card and chassis backplane.
Interface card connectors are bought to the cabinet face.
LEXU-B1A
BPTU1A
RDTU3A
Optional
LCNU-A1A BSTCIU1A Optional
Plugs into the 50-pin Amphenol socket on the interface card.
Extends modular connectors to the CIX200 chassis face.
LCNU-B1A
BWDKU1A
BDKU/
BDKS
Optional
LCNU-C1A
RCOU3A
RGLU3A
RDDU2A
BCOCIU1A
Optional
(See
Comments
Plugs into the modular connectors on the interface card.
Extends modular connectors to the CIX200 chassis face.
The LCNU-C1A connects the CO lines and Caller ID in one
connector. If not used the connections must made on the
MDF.
LCNU-D1A REMU1A Optional
Plugs into the modular connectors on the interface card.
Extends modular connectors to the CIX200 chassis face.
LCNU-E1A RCIU2A
Required
(See
Comments)
The LCNU-E1A is a set of small cables. These are required
only if the LCNU-C1A is used. Connects RCIU2A to the
LCNU-C1A to connect the Caller ID and CO line together in
one modular socket.
LPFU1A
Power Fail
Transfer
Required
Required for power fail transfer operation. The LPFU1A is
two extender cards and two cables. The CO and Station
cards must be in adjacent slots.
LCNU-A1A
LCNU-B1A LCNU-C1A
LCNU-D1A
LCNU-E1A