Specifications
Strata CIX40
Additional Specifications
Strata CIX General Description 08/14 13
Additional Specifications
Table 6 CIX40 Specifications
Category Items Specification Remarks
Power
Input voltage rating 100-240VAC
Input current rating 1.3A max. At full installation
Input frequency 50/60 Hz
AC adapter output
voltage
+15V/4.0A
Voltage of inside
Power switch
-27.3V/+5.0V
DC Switch Located inside cabinet
Power failure back up
1 HPFB6: 1 hour
2 HPFB6: 2 hours
See page 11
The amount of time depends on
hardware configuration. One hour
in HPFB6 means 6 CO+16DP with
GVPH based on HPFB6 is fully
charged.
Grounding
Customer supplied
Grounding wire.
Ground wire must connect the
earth ground through the FG
terminal on the GMAU for safety
purposes and to protect noise.
AC Plug 2-pin (American)
Ground wire must connect the
earth ground through the FG
terminal on the GMAU for safety
purposes and to protect noise.
Environment
Operating
Temperature
0 - 40 C
Operating humidity 20 - 80%
Storage temperature -20 - 60 C
Safety
System
Maximum ports 40 16: DP phones
6: Analog trunk
8: IP channel
4: Voicemail
2: Analog devices
4: Serial ports
Regulation
Safety UL60950-1
USAEMC FCC part15 class-A
Network Performance FCC part68
FCC/ACTA
Registration
Numbers
ACTA/FCC Part 68 Registration for Key System Code (KD): CJ6KD03BDTCHS402
ACTA/FCC Part 68 Registration for Multifunction Code (MF): CJ6MF03BDTCHS402
ACTA/FCC Part 68 Registration for Multifunction Code (PF): CJ6PF03BDTCHS402