Specifications

Appendix – Specifications
Capacities
224 Strata CIX General Description 08/14
Ring Tones (Internal Call Ring Tones for DPs
and IPTs)
10 10 10 10 10
Speed Dial - Station SD numbers per system
6
8400 8400 2400 5600 2400
Speed Dial - Station SD numbers per Station
(allocated in increments of 10)
Min: 0
Max: 100
Min: 0
Max: 100
Min: 0
Max: 100
Min: 0
Max: 100
Min: 0
Max: 100
Maximum stations with SD per system
840 840 240 560 240
Speed Dial - System SD numbers per system
800 800 800 800 800
Stratagy Voice Processing per system
111 1 1
Tenants
888 8 8
Destination Restriction Level (DRL) Classes
16 16 16 16 16
Verified Account Codes
4000 4000 3000 1000 300
Voice Mail SMDI Interface
1
111 1 1
External Ring Repeat - to available stations
256 256 All All All
LCR Exception Table Size
(Programs 521 and 522)
2500 2500 2500 1280 1280
Maximum number of digits in the LCR
Modified Digits Table
19 19 19 19 19
Maximum number of LCR Route Plans
128 128 128 64 64
CSTA Device Monitors
7
1152 1152 1152 512 512
CSTA Call Monitors
8
560 560 560 320 320
1. SMDI and SMDR may require BSIS serial port or LAN interface.
2. Conference circuits are used dynamically, so the maximum number of simultaneous conferences is
affected by the number of conference members in each conference. The total number of members in
simultaneous conferences cannot exceed the total number of conference circuits. Each conference can
have up to eight members. Two CO line connections do not require a conference circuit.
3. DTMF receivers are required for standard touch tone telephones, voice mail integration, Tie, DID and
DISA lines.
4. An option BIOU is required for up to four zone page relays and four control relays on the CIX670 and
CIX1200 processor.
5. On Digital telephones Speaker OCA capacity is determined by 2B channel slot availability and power
supply. S-OCA requires the DOCA-1A option in DP5000-series digital telephones, but not in IP
telephones. Speaker OCA on IP telephones require an MIPU or LIPU installed in the Strata CIX. Each IP
telephone with Speaker OCA requires two IP channels on the MIPU / LIPU but only requires one IP
endpoint license. The IP OCA channel is only used while the S-OCA call is in progress so it can be
reserved or shared with other telephones for S-OCA but cannot be used as a dedicated IP channel for
another telephone or Strata Net channel. DP5008 and IPT1020-SD and IP2000-series telephones do not
support Speaker OCA; all other current Toshiba telephones support S-OCT.
6. Up to 100 Station SD numbers, allocated in increments of 10, can be programmed per station.
7. See “Device Monitor Capacities for Strata CIX Systems” on page 225.
8. See “Device Monitor Capacities for Strata CIX Systems” on page 225.
Table 67 Strata CIX1200 and CIX670 System Feature Capacities (continued)
Features
CIX1200
EXP. B
HEXBU
CIX1200
EXP. A
HEXAU
CIX1200
Basic
HCTU Only
CIX670
Expanded
Processor
BCTU +
BEXU
CIX670
Basic
Processor
BCTU