Specifications

Appendix – Specifications
IP Telephone Power Consumption
206 Strata CIX General Description 08/14
IP Telephone Power Consumption
The power consumption for the IP5000-series telephones and the Add-on modules is shown in Table 48.
Use this information to calculate the Power over Ethernet (PoE) requirements and UPS capacity.
Table 48 IP Telephone and Add-On Module Power Consumption
Telephone
Model
1
1. Power ratings are only telephone and option modules consumption. The values do not include LAN
cable power loss, and apply to PoE, not local power supplies.
Option
Power Rating
(Watts)
Current
(A)
2
2. Power ratings are only telephone and option modules consumption. The values do not include LAN
cable power loss, and apply to PoE, not local power supplies.
Typical
(Watts)
3
3. Typical means that it is only an example and there is no guarantee implied. The "typical" value might be
used for a calculation of actual UPS backup time in an average installation.
Typical
Current (A)
4
4. Typical Current (A) = Typical Watts / 48 v
IEEE802.3af
PD Class
Model Qty
IP5122-SD none -- 7.4 0.15 6.2 0.13 0
IP5122-SDC none -- 7.4 0.15 6.2 0.13 0
IP5132-SD none -- 7.4 0.15 6.2 0.13 0
IP5131-SDL none -- 7.4 0.15 6.2 0.13 0
IP51xx + IDM5060 3 10.3 0.21 8.6 0.18 0
IP51xx + IDM5060 2 9.4 0.20 7.8 0.16 0
IP51xx + IDM5060 1 8.4 0.18 7.0 0.15 0
IP51xx + LM5110 2 10.3 0.21 8.6 0.18 0
IP51xx + LM5110 1 9.4 0.20 7.8 0.16 0
IP51xx + KM5020 2 8.9 0.19 7.4 0.15 0
IP51xx + KM5020 1 8.2 0.17 6.8 0.14 0
IP5622-SD none -- 3.7 0.08 3.0 0.06 1
IP5631-SDL none -- 4.1 0.08 3.3 0.07 2
IP5631-SDL IDM5060 3 6.4 0.13 5.4 0.11 2
IP5631-SDL IDM5060 2 5.6 0.12 4.7 0.10 2
IP5631-SDL IDM5060 1 4.8 0.10 4.0 0.08 2
IP5631-SDL LM5110 2 6.4 0.13 5.3 0.11 2
IP5631-SDL LM5110 1 5.6 0.12 4.7 0.10 2
IP5631-SDL KM5020 2 5.2 0.11 4.3 0.09 2
IP5631-SDL KM5020 1 4.6 0.10 3.9 0.08 2