Specifications
Appendix – Specifications
Public Network Requirements
200 Strata CIX General Description 08/14
Public Network Requirements
The Circuit Card requirements for connecting to the public network are shown in Table 42.
Table 42 Circuit Card Network Requirements
Circuit Card Interface Facility Interface Code Network Jack
Ringer
Equivalence
Universal Service
Order Code
BSTU
1
/RSTU3/RDSU
2
(Off-premises Station)
1. BSTU parameters: Loop current 25mA to 35mA.
Maximum loop resistance allowed:
600ohm each without R48S1A - Class B (FCC Part 68)
1200ohm each with R48S1A - Class C (FCC Part 68)
Impedance: 600ohm
2. Only RDSU ckts. 1~4 provide Off-premises Station (OPS) ability. RDSU must use OL13A or OL13B if providing
–24 volt loop voltage. If equipped with the –48 volt loop option circuit card (R48S), OL13A, OL13B, or OL13C
may be used for OPS connection.
OL13B (RSTU3, –24V)
OL13C (RSTU3, RDSU with
R48S-48V)
RJ21X N/A 9.0F
BSLU/BSLS
3
CIX40 Standard
Telephone Interfaces
3. Supports one ringer per circuit. Does not support Message Waiting Lamp or OPS.
OL13B (–24V) RJ21X N/A 9.0F
BSTCIU (Analog Station
4
with Caller ID)
4. BSTCIU parameters: Loop current 25mA to 35mA.
Maximum loop resistance allowed:
600ohm each without R48S1A - Class B (FCC Part 68)
1200ohm each with R48S1A - Class C (FCC Part 68)
Impedance: 600ohm
Ring cadence: On 2 sec., Off 4 sec. (Use for Caller ID) or On 1 sec., Off 3 sec.
OL13B (–24V)
OL13C (with R48S-48V)
RJ21X / RJ11C N/A 9.0F
RCOU/RCOS
5
(loop start line)
5. Loop current requirements for Strata loop and ground start lines: 20 milliamperes (mA) min./120 mA max.
02LS2
RJ14C/RJ21X
(all others)
0.3B N/A
RCIU2/RCIS (Caller ID) N/A RJ21X/RJ14C 0.3B N/A
BCOCIU/BCOCIS
CIX40 CO Line Interfaces
02LS2
RJ21X / RJ11C /
RJ14C
0.3B N/A
RDDU
02RV2-T (Dealer-supplied
CSU)
RJ14C/RJ21X 0.0B AS.2
REMU type 1 or type 2
TL11M, 2-wire
TL31M, 4-wire
TL12M, type 2, 2-wire
TL32M, type 2, 4-wire
RJ2EX
RJ2GX
RJ2FX
RJ2HX
Not Available
(N/A)
9.0F
RGLU3 (ground or loop
start line)
2
02GS2 (ground)
02LS2 (loop)
RJ14C/RJ11CX 0.3B N/A
RDTU (DS-1/T1)
6
(See last bullet note on Note 2
below.)
RJ48C/RJ48X/
RJ48M
N/A 6.0P
BPTU, RPTU (PRI)
7, 8
04DU9-1SN (Dealer-supplied
CSU)
RJ48C/RJ48M
N/A 6.0P
BPTU, RPTU (Strata Net)
04DU9-1SN (Dealer-supplied
CSU)
RJ48C/RJ48M
RMCU/RCMS (CAMA) 02RV2-O RJ11C/RJ21-X