Specifications

Strata Media Application Server and Integrated Voice Mail Cards
Input Power
82 Strata CIX General Description 08/14
Input Power
The MAS is supplied with a standard 15 Amp power cord with a standard three-prong 120 VAC that
plugs into an AC power outlet. The MAS requires:
A dedicated, properly grounded circuit
Note No additional grounding is required provided the AC outlet is properly grounded.
An input power source of 120 VAC, 50 or 60 Hz, 5.67 amps (max)
Power Failure Backup
Customer-supplied commercially available UPS systems should be used for power failure backup.
Grounding
The MAS does not need any additional grounding provided the AC outlet is properly grounded.
Connection
The MAS connects to the CIX using IP connections. All of the feature communications and Voice
Mail speech paths are carried by these connections.
The monitor, keyboard and mouse are customer-supplied options. The MAS can be accessed via
the network by using the Windows® XP Remote Desktop feature.
Figure 18 MAS Connection Block Diagram
CIX
MAS
Network Switch
*Monitor
*Key Board
*Mouse
LAN
*Optional
MIPU/LIPU
Processor
LIPS/GIPU/GIPH