User Manual

PARAMETER REFERENCE MANUAL90
Page A
Value Meaning
ysEx Page A parameters are transmitted/received as system exclusive packets. Controller
data reception is disabled.
Controller Data Page A parameters are transmitted/received in the form of MIDI CC (see glossary)
data.
Page B
Value Meaning
ysEx Page B parameters are transmitted and received in the form of system exclusive
packets. Controller data reception is disabled.
Poly Pressure Page B parameters are transmitted and received in the form of Poly-pressure data.
Inputs
Boost
0 to 127: Boosts the input - use this only for very low level signals.
Input Thru
0 to 127: The level of external signal sent directly to output 1.
Sensitivity
+16 dBV .. -16 dBV: Select sensitivity to suit different external audio sources.