User manual

7
Manual WM-IIRO-8
Chapter 2: Installation
POWER
WM-IIRO-8 Plug the provided AC wall adaptor to any standard AC wall outlet.
WIRELESS SERIAL MODEM
Laptops: Plug the provided AC wall adaptor to any standard AC wall outlet.
Desktops: Install the provided two section power cable. The Molex ~ DB9-F cable
section goes inside the host computer. The DB9-M ~ Modem cable goes
outside the host com puter.
SERIAL COMMUNICATION
Plug the provided DB9-F / Modem cable into one of the host computer’s COM Ports. The COM
Port selected MUST be configured for the following settings:
Protocol: RS232
Baud Rate: 9600
Data Bits: 7
Parity: Even
Stop Bits: 1
VERIFY INSTALLATION
1. Locate and run ACCES WINRISC.EXE application program (easy-to-use serial
com munication terminal program ) on the CD-R OM provided at :\disks\Tools.win\W IN32\.
2. Match the pull-down menu settings to the appropriate ‘Port’ and above configuration.
3. Click the “Connect” button to connect the application to the Wireless Serial Modem then
click the cursor into the large “data” area of the WINRISC window.
4. Type “?” and press enter. A “Main Help Screen” will be returned if the two units have
been installed properly.