User manual
Manual WWP-IIRO-8
15
Relay Outputs
• Number: Eight
• Contact Form: SPDT (form C)
• Contact Type: Single Crossbar
• Contact Material: Silver + Gold-clad
• Rated Load: 0.5 A at 125 VAC; 1 A at 24 VDC
• Max. Switching Current: 1 A
• Max. Switching Voltage: 125 VAC; 60 VDC
• Max. Switching Capacity: 62.5 VA; 30 W
• Contact Resistance: 100 mΩ max.
• Operate Time: 5 ms
• Release Time: 5 ms
• Contact Life (mechanical): 5 million operations
Environmental
• Operating Temperature Range: 0°C to 65°C
• Temperature De-rating: Based on the power applied, maximum operating temperature may have
to be de-rated because internal power regulators dissipate some heat.
For example, when 7.5VDC is applied, the temperature rise inside the enclosure is 7.3°C above the
ambient temperature.
Maximum operating temperature can be determined according to the following equation:
V
I(TJ = 100)
< 19.6 - T
A
/6.83
Where T
A
is the ambient temperature in °C. and V
I(TJ = 100)
is the voltage at which the integral voltage
regulator junction temperature will rise to a temperature of 100 °C.
(Note: The junction temperature is rated to 120 °C. maximum.)
For example, at an ambient temperature of 25 °C., the voltage V
I
can be up to 15.9V.
At an ambient temperature of 100°F (37.8°C), the voltage V
I
can be up to 14V.
• Storage Temperature Range: -20 °C. to +70 °C.
• Humidity: 5% to 95% RH non-condensing.