Technical information
V4 Logger49
© 2010 OMT Technologies
V4 Logger
Feed Creation - Continued:
To configure the split closure, select the box to the right of the split file closure display and select
the appropriate closure device and pin assignment.
Under “Split Delay”, set the desired time for the Logger to “wait” until the recording resumes. When
configuring your pre-recorded satellite or external event, this will be based on the provider schedule
clock that outlines the duration of the commercial stopset.
NOTE: Different length wait or stopset times can be scheduled under the “Scheduler” section outlined
later in this guide.
Pause Closure
The Pause feature acts the same as the “old school” cassette or reel to reel machine where a remote
switch closure would continue the recording and when open would stop the recording but leave the
device in a record/pause mode. The end result is a recording that does not contain minutes of dead
air when using closure based recordings such as mic skims.
Any valid closure device can be assigned for the incoming closures as with the previous Input, Output,
and Split closure functions. There is also a delay with an adjustable value of 0 to 5000 ms (5
seconds) to compensate for the inherent delay on WAN or Internet based audio feeds.
The “Pause on Start” can be enabled to place the feed item in record/pause mode initially.