Technical information
V4 Logger User Guide 32
© 2010 OMT Technologies
V4 Logger
Configuration - Continued:
Perform Silence Detection
The above screen shot displays the “Perform Silence Detection” section. This is enabled by default
and will flash the “Silence” warning from the Record/Meter section on the left hand column of the
Logger application independently for each audio channel.
If you have a closure device installed such as the DIO 24H PCI card in the following example, you can
assign a closure for either “When any channel is silent” or “When no channel is silent”. Select the
“Edit” box directly to the right of both function and the select the appropriate pin based on your
installed closure device. You can enable one of the two available functions if desired.
The “Allowed Silence Threshold” does not reference from a specific zero reference point. To
accurately set both the “Allowed Silence Threshold” and “Auto Trim” levels, use a known or fixed
output such as a reference tone or tone generator.
Auto Trim
NOTE:
It is strongly recommended NOT to use the auto trim feature on a large number of scheduled
database recordings as this will place a significant amount of overhead on the Logger computer,
especially with 8 and 12 channel versions. Use discretion when applying this feature to ensure
reliability and functionality.