Operating instructions

TransTel Model TD-824-I Digital Telephone System - General Description - Installation - Programming Forms Manual
Page 70 Version 1.3b October 2005
Includes all versions through G1-a20x
Form 05-14 - System Parameters Form – Miscellaneous
Form 05-14-T 01 02 03 04 05 06 07 08
Item
Range Of Entries 0-8 0 0 0 -1 0-9 0 0 0
Default 0 0 0 1 0 0 0 0
05-14-01 – ISDN PLL Maintenance:
This parameter controls the function of the internal phase locked loop, used for ISDN trunking.
If set to 0, the system relies on it’s internal clock to remain synchronized with ISDN lines.
0=Disable
1=Every hour search an active
ISDN Link for synchronization
2~8=Use the ISDN circuit specified
for synchronization (2-8)
05-14-02 – Reserved:
05-14-03 – Reserved:
05-14-04 – Trunk Metering Detection:
This parameter detemines which method of trunk metering will be used.
Note: This parameter is not used in North America.
0=Detect 16K meter pulses 1=Detect 12k meter pulses
05-14-05 – Caller ID Delay Ring Timer:
In applications using Caller ID, it may be necessary to delay the start of incoming ringing in order to allow Caller
ID be to sent to the telephone system. This timer will cause the system to delay ringing up to the time selected in
this timer or until a valid Caller ID record is received, whichever occurs first.
0=disable 1~9=Delay n seconds or until valid CID record received
05-14-06 – Reserved:
05-14-07 – Reserved:
05-14-08 – Reserved: