Operating instructions

TransTel Model TD-824-I Digital Telephone System – Programming Forms Manual
Page 55
Form 05-06 - System Parameters Form - Timer/Codes
Form 05-06- 01 02 03 04 05 06 07 08
Item
Range Of Entries 0 - 9 0 - 9 0 0 - 1 0 - 1 0-9 0, 1, 3 0
Default 4 4 0 1 0 3 0 0
05-06-01 - Transfer Recall Timeout-Busy (seconds):
This parameter sets the time duration between transferring a call to a busy party and automatic
transfer back to the transferring party when the called party remains busy
0=5 1=10 2=15 3=20 4=30
5=40 6=50 7=60 8=70 9=No Recall
05-06-02 - Transfer Recall Timeout-No Answer (seconds):
This parameter sets the time duration between transferring a call to a station and automatic transfer
back to the transferring party when the called party does not answer.
0=5 1=10 2=15 3=20 4=30
5=40 6=50 7=60 8=70 9=No Recall
05-06-03. ISDN Audio:
This parameter sets ISDN Audio type.
0 = a law 1 = u law
05-06-04 - Polarity Reverse Detection:
This parameter is to enable the Polarity Reversal detection feature for incoming caller hang up
detection in Australia and some European countries. See Mode 14-01-08 for SMDR setting. Telecom
will need to enable polarity reversal at the exchange. When reversal is enabled the system will hang
up the exchange line when the incoming caller hangs up and the exchange sends a reversal to the
system.
0 = Disable
1 = Enable for 1 polarity reverse signal
2-9 = Delay for 1-8 Seconds and then detect Polarity Reverse Signal
0=Enable 1=Disable
05-06-05 - Operator Access Code:
This parameter is to set whether to dial "0" or "9" for the operator or for accessing a CO. line.
0 = 0 Operator - 9 Outside Line 1= 9 Operator - 0 Outside Line