Operating instructions
TransTel Model TD-824-I Digital Telephone System - General Description - Installation - Programming Forms Manual
Page 48 Version 1.3b October 2005
Includes all versions through G1-a20x
Form 02-05 Continued
05-02 05 - Key Telephone Flash Timer (ms. = milliseconds):
This parameter permits the selection of Flash time for Key stations when pressing the [TRF/FL] key
or an analog phone which presses flash and then dials 800 while connected to an outside line. After
dialing 800 the flash signal will be sent to the CO line and the analog phone will reconnect to the line
0=80 ms. 1=120 ms. 2=200 ms. 3=280 ms. 4=440 ms.
5=640 ms. 6=840 ms. 7=1040 ms. 8=1240 ms. 9=1440 ms.
05-02-06. SLT Hold Signal:
This parameter permits the selection of the Flash time from a single line telephone that the system
will see as a Hold signal if the time is greater than the hold signal but less than the SLT release time.
DURING
CONVERSATION
HOOK PRESSED-Period B
HOOK RELEASED
Period B < SLT Release Time Hold
DURING
CONVERSATION
HOOK PRESSED-Period B
HOOK RELEASED
Period B > SLT Release Time Hang Up
0=64 ms. 1=80 ms. 2=104 ms. 3=200 ms. 4=304 ms.
5=400 ms. 6=512 ms. 7=600 ms. 8=704 ms. 9=800 ms.
05-02-07 - Minimum Ring Detection (Ring On) Timer (ms. = milliseconds): Minimum ring burst
that must be present for the system to detect an incoming call.
0=0 ms. 1=160 ms. 2=240 ms. 3=360 ms. 4=440 ms.
5=560 ms. 6=640 ms. 7=760 ms. 8=840 ms. 9=960 ms.
05-02-08 - Ring Cycle (Ring Off) Timer: Length of time that the system must have without a ring
signal for the system to stop internal ringing (abandoned calls).
0=2 seconds 1=2 seconds 2=2 seconds 3=3 seconds 4=4 seconds
5=5 seconds 6=6 seconds 7=7 seconds 8=8 seconds 9=9 seconds