Operating instructions

TransTel Model TD-824-I Digital Telephone System – Programming Forms Manual
Page 47
Form 05-02 - System Parameters Form - Timers-2
Form 05-02- 01 02 03 04 05 06 07 08
Item
Range Of Entries 0-9 0-9 0-9 0-9 0-9 0-9 0-9 0-9
Default 5 5 1 8 4 3 2 6
05-02-01. SLT Dial Tone Timeout:
This parameter is for Single Line Telephones. If a key is not pressed before the assigned time period
expires when Dial Tone is given, a Busy Tone will be heard and the DTMF receiver will be released.
05-02-02. SLT Inter-Digit Timeout:
This parameter is for Single Line Telephones. If the interval between digits dialed exceeds the
assigned time period, a Busy Tone will be given and the DTMF receiver will be released.
0=0 second 1=2 seconds 2=4 seconds 3=6 seconds 4=8 seconds
5=15 seconds 6=30 seconds 7=60 seconds 8=120 seconds 9=254 seconds
05-02-03. Auto Redial Ringing Time – CO lines:
This parameter is the time duration for which the system will redial the telephone number
automatically and then hang up during Auto Redial on CO lines. ISDN lines will hang up immediately
if the called number is busy.
Off Hook Auto-Redial Pause Time
(Program 05-05-08), Y seconds
Off Hook
Auto-Redial Ringing
Timer
On Hook Auto-Redial Ringing Timer
0=1 second 1=10 seconds 2=20 seconds 3=30 seconds 4=40 seconds
5=50 seconds 6=60 seconds 7=70 seconds 8=80 seconds 9=90 seconds
05-02-04. SLT Release Signal:
This parameter is the time duration of depressing the hook switch of an SLT that the system will see
as a hang up, the system will take it as a hold signal if less than this time but longer than the SLT
hook flash time.
0=40 ms. 1=80 ms. 2=120 ms. 3=400 ms. 4=600 ms.
5=800 ms. 6=1000 ms. 7=1200 ms. 8=1400 ms. 9=1600 ms.