Operating instructions
TransTel Model TD-824-I Digital Telephone System – Programming Forms Manual
Page 45
Form 05-01 - System Parameters Form - Timers-1
G1-a20m G1-a20t
01 02 03 04 05 06 07 08
Form 05-01-
Range of Entries
0-9 0-9 0-9 0-9 0-9 0-9 0-9 0-9
Default Value
1 1 1 1 4 2 2 1
Item Valid
Settings
Description Default
05-01-01 0-9 Hold Recall Time 1=60 Sec
05-01-02 0-9 Exclusive Hold Recall Time 1=60 Sec
05-01-03 0-9 Hold Recall Timeout 1=60 Sec
05-01-04 0-9 DISA Access Delay Day Service
G1-a20m
1=2 Sec
05-01-05 0-9 Busy Remind Cycle Time
G1-a20t
4=8 Sec
05-01-06 0-9 Pause Time 2=800 Ms
05-01-07 0-9 DTMF Generation Time 2=83 Ms
05-01-08 0-9 Call Forward No Answer TRF. Time 1=20 Sec
05-01-01. Hold recall time:
This parameter sets the time duration from when Hold is initiated to when the held call starts to ring
(recall) the station.
After a pre-determined recall time (see 05-01-03: Hold Recall Timeout), if the station still does not
answer, the hold call will automatically transfer to the Console.
05-01-02. Exclusive Hold recall time:
This parameter sets the time duration from when Exclusive hold is initiated to when the held call starts to
recall the station.
After a pre-determined recall time (see 05-01-03: Hold Recall Timeout), if the station still does not
answer, the held call will recall to the Console in addition to the holding station.
05-01-03. Hold Recall Timeout:
This parameter sets the time between a call recalling to a holding or transferring station and then
recalling to the console if unanswered.
See Values below for these timers.
0=30 seconds 1=60 seconds 2=90 seconds 3=120 seconds 4=150 seconds
5=180 seconds 6=210 seconds 7=240 seconds 8=253 seconds 9=No recall