Operating instructions
TransTel Model TD-824-I Digital Telephone System - General Description - Installation - Programming Forms Manual
Page 130 Version 1.3b October 2005
Includes all versions through G1-a20x
Form 59 - Exception (Allow) Tables:
Entry
Number
Actual Entry (Up to 12 digits in Length)
Entry
Number
Actual Entry (Up to 12 digits in Length)
01 09
02 10
03 11
04 12
05 13
06 14
07 15
08 16
Toll Control Examples
This example is based on a location where 911 is enabled and all local calls are placed by dialing a 7 digit number.
The customer wants calls only allowed to 911 and 1-800, 1-888 and 1-877.
Set Form 41-11-05/06 = 7
When this form is set and Form 57 is still at default then station 11 will be totally restricted.
Set form 57 to the following,
Form 57-01 = 911ddddddddd
Form 57-02 = 1800dddddddd
Form 57-03 = 1888dddddddd
Form 57-04 = 1877dddddddd
Station 11 will now be only able to dial:
911
1-800-xxx-xxxx
1-888-xxx-xxxx
1-877-xxx-xxxx
Example 2
All except 0 and 1 plus, but allow 1-800, 1-888, 1-877.
Set Mode 41-11-05/06 = 1
When this mode is set and Mode 51 and 61are still at default then station 11 will be unrestricted.
Set Mode 61 to the following,
Mode 61-01 = 0 (remove all trailing d digits)
Mode 61-02 = 1ddddddddddd
Station 11 will now be only able to dial numbers beginning with digits 2 through 9.
Mode 52-01 = 1800dddddddd
Mode 52-02 = 1888dddddddd
Mode 52-03 = 1877dddddddd
Station 11 can now dial calls beginning with 1-800, 1-888 and 1-877.