Operating instructions

TransTel Model TD-824-I Digital Telephone System - General Description - Installation - Programming Forms Manual
Page 104 Version 1.3b October 2005
Includes all versions through G1-a20x
Form 40 - Station Class of Service (Part 1):
Item
Valid
Settings
Description
Default
40-st-01 0-9,d Override/OHCA Level 1=Low
40-st-02 0-9 Monitor Level 1=Low
40-st-03 0-9 Limit Call Duration 0=No
40-st-04 0-1 Station Loud Bell 0=No
40-st-05 0-1 Access Paging 0=Yes
40-st-06 0-1 Receive Paging 0=Yes
40-st-07 0-1 Security Code Status 0=None
40-st-08 00-48 Forced Account Code 00=All
40-STN-01 – Override and OHCA Level:
Higher level stations can override lower level stations, equal levels may override each other.
0=Unable to Override 1-9=Can Override equal and lower numbered levels
40-STN-02 - Monitor Level:
Higher level stations can monitor lower level stations, equal levels can not monitor each other.
0=Unable to Monitor 1-9=Can Monitor lower numbered levels
40-STN-03 - Call Limit Duration:
Conversation will be interrupted by a BusyTone. A warning tone will be given 10 seconds before the end of the
timed duration. (see form 05-04-03 to set call limiting action)
0=No Duration Limit 1=3 minutes 2 = 5 minutes
3 = 10 min 4 = 15 minutes 5 = 20 minutes
6 = 30 minutes 7 = 40 minutes 8 = 50 minutes
9 = 60 minutes
40-STN-04 - Associated Loud Bell:
0=Disabled 1=Use Relay on MSC Card
The system does not provide any voltage from the assigned relay. A separate ring voltage and ring device will
need to be provided by the installer.
40-STN-05 - Paging Access:
Stations will be able to page only if this option is enabled.
0=Enable 1=Disable
40-STN-06 - Paging Over Speaker:
This feature is useful for someone who should not be disturbed by paging calls.
0="All Page" can be received by this station 1= "All Page" can not be received by this station