Operating instructions

TransTel Model TD-824-I Digital Telephone System – Programming Forms Manual
Page 103
Form 39-st Sensor Assignment Form – ACP and Doorphone Units:
G1-a10aq
The SENSOR type may be normally open or normally closed
Form 39-st- 01 02 Name - (Reference Only – Not programmed in
system)
Form 39-
Starting with software version G1-a10aq, the ability was added to the system to program the sensors that
accompany each Digital Doorphone Unit and ACP. Valid settings are:
00=Can provide two different methods of operation.
If 50-ACP-01 is set to 0, then the sensor is not programmed.
If 50-ACP-01 is set to 1, then the sensor is configured as a latching fire alarm.
Sensor detects activation, all idle extensions will be rung and all busy extensions will
Hear the alarm tone. The fire alarm will continue for 10 minutes.
Pressing [7][7][7] from the console will stop the fire alarm.
01=Non-Latching Operation (Break Alarm)
When activated, all idle extensions will be rung.
When deactivated, all extensions will stop ringing.
03=Non-Latching Operation with LED indication
When activated, all idle extensions will be rung. Any extensions with a DSS appearance of the Door Phone Unit
will see a flashing indication while the alarm is active.
When deactivated, the signal disappears, all extensions will stop ringing LED will extinguish.
Valid Idle Options for Sensor Item Settings 39-02:
0 = Disable Sensor function
1 = Normally Open, Activates on sensor close
2 = Normally Closed, Activates on sensor open