Installation guide
Configuring the MMP
Acano solution: Single combined Acano server Deployment Guide R1.6 76-1054-01-H
Page 17
3.3 Configuring the Web Admin Interface for HTTPS Access
The Web Admin Interface is the Call Bridge’s user interface. You should have set up the
certificate for the Web Admin Interface (by following one of the Installation Guides). If you have
not, do so now.
1. The port for the Web Admin Interface is 443 UNLESS you configured the Web Admin
Interface access on the same interface as the Web Bridge. Then set the default TCP port to
a non-standard port such as 445 to allow the Web Bridge to function on TCP port 443 with
the command
webadmin listen admin 445.
2. To test that you can access the Web Admin Interface, type your equivalent into your web
browser: https://acanoserver.example.com.
If it works, proceed to next section.
3. If you cannot reach the Web Admin Interface:
a. Sign into the MMP, type the following and look at the output:
webadmin
The last line of the output should say "webadmin running".
b. If it does not there is a configuration problem with your Web Admin Interface. Check that
you have enabled it by typing:
webadmin enable
c. The output of the webadmin command should also tell you the names of the certificates
you have installed, e.g. webadmin.key and webadmin.crt.
Note: They should the same names of the certificates you uploaded previously.
Assuming these are the names then type:
pki match webadmin.key webadmin.crt
This will check that the key and certificate match.
d. If you are still experiencing issues, troubleshoot the problem as explained in the
Certificates guidelines document.
3.4 Configuring the Call Bridge
The Call Bridge needs a key and certificate pair that is used to establish TLS connections with
SIP Call Control devices and with the Lync Front End (FE) server. If you are using Lync, this
certificate will need to be trusted by the Lync FE server.
The command callbridge listen <interface> allows you to configure a listening
interface (chosen from A, B, C or D). By default the Call Bridge listens on no interfaces; see the
MMP Command Reference.
1. Create and upload the certificate as described in the Certificate guidelines document.
2. Sign into the MMP and configure the Call Bridge to listen on interface A.
callbridge listen a