SDS

Safety Data Sheet
IDQ Operating, Inc.
44 Old Ridgebury Road
Suite 300
Danbury, CT 06810
Tel. 1-203-205-2900
IDQ ACP-100 Page 2 of 6
rapid suffocation.
If skin irritation occurs: Get medical attention.
Take off contaminated clothing and wash it before reuse.
IF exposed or concerned: Get medical attention.
Store locked up.
Protect from sunlight. Do not exposure to temperatures
exceeding 50°C / 122°F.
Dispose of contents and container in accordance with
local and national regulations.
3. Composition/Information On Ingredients
Component
CAS No.
Amount
1,1,1,2-tetrafluoroethane
811-97-2
80-85%
Polyalkylene glycol monobutyl ether
Proprietary
5-15%
Additive Package
Proprietary
1-10%
Oil Additive
Proprietary
<1%
Methylene chloride
75-09-2
<1%
The exact concentrations are a trade secret.
4. First Aid Measures
Inhalation: If symptoms of exposure develop, remove to fresh air. Seek medical attention if breathing problem or
irritation persists.
Skin Contact: Wash exposed skin with soap and water. If skin irritation or redness develops, seek medical
attention.
Eye Contact: Flush eyes with large amounts of water for several minutes. If irritation or other symptoms develop,
seek medical attention.
Ingestion: Ingestion is an unlikely route exposure for aerosol products.
Most Important Symptoms: May cause mild eye irritation. Mists may cause mild respiratory irritation. Exposure to
high concentrations can induce anesthetic effects progressing from dizziness, weakness, nausea, to
unconsciousness. Causes skin irritation. May damage fertility or the unborn child. May cause cancer.
Indication of Immediate Medical Attention/Special Treatment: None known.
5. Firefighting Measures
Suitable (and Unsuitable) Extinguishing Media: Use extinguishing media suitable for surrounding fire. Cool fire
exposed containers with water.
Specific Hazards Arising from the Chemical: Contents under pressure. Exposure of containers to heat and
flames can cause them to rupture often with violent force. Burning may produce oxides of carbon and fluoride; and
hydrogen fluoride.
Special Fire Fighting Procedures: Firefighters should always wear positive pressure self-contained breathing
apparatus and full protective clothing. Cool fire-exposed containers with water. Use shielding to protect against