SDS
IDQ, Inc. Material Safety Data Sheet May 9th, 2011
Garland, Texas 760 Auto HVAC Duct Cleaner
2
Skin Contact: Wipe off with towel. Wash with soap and water. If skin irritation persists, get medical attention.
SECTION 5: FIRE FIGHTING MEASURES
Unusual Hazards: Closed containers may explode from internal pressure build-up when exposed to extreme heat
And discharge contents. Liquid content of container will not support combustion. Overexposure to decomposition
products may cause a health hazard. Symptoms may not be readily apparent. Obtain medical attention
Extinguishing Agents: N/A
Personal Protective Equipment: Wear self-contained breathing apparatus and full protective gear.
Special Precautions: Water spray may be ineffective. Water may be used to cool containers to prevent
pressure build-up and explosion when exposed to extreme heat. If water is used, fog nozzles preferred,
wear goggles and self contained breathing apparatus.
FIRE AND EXPLOSIVE PROPERTIES:
PROPERTY PACKAGED PRODUCT LIQUID PORTION OF PRODUCT
Flash Point (°C); [°F]: Non-Flammable at STP Non-Flammable at STP
Auto-Ignition Temperature (°C):
Lower Explosive Limit (ppm): Non-Flammable at STP Non-Flammable at STP
Upper Explosive Limit (ppm): Non-Flammable at STP Non-Flammable at STP
SECTION 6: ACCIDENTAL SPILL OR LEAK RELEASE INFORMATION
Personal Protection: Appropriate protective equipment must be worn when handling a large spill of this material.
See the PERSONAL PROTECTION MEASURES Section for recommendations. If exposed to material during
clean-up operations, see the FIRST AID PROCEDURES Section for actions to follow.
Procedures: Evacuate the spill area. Floor may be slippery if non-volatile components in product have wetted the
floor; use care to avoid falling. Ventilate the spill area. Avoid breathing vapor. Contain non-volatile material spills
immediately with inert adsorption materials. Transfer liquids and solids absorption materials to separate suitable
containers for recovery or disposal.
CAUTION: Keep spills and cleaning runoff out of municipal sewers and open bodies of water.
SECTION 7: HANDLING AND STORAGE
Storage Conditions: Store and use in cool, dry, well-ventilated areas. The maximum storage temperature is 49° C/
120° F.
Handling Procedures: Do not puncture or incinerate (burn) cans. Do not stick pin, nail or any other sharp object