CONTROLLER 67 USER MANUAL
WELCOME Thank you for choosing AC Infinity. We are committed to product quality and friendly customer service. If you have any questions or suggestions, please don’t hesitate to contact us. Visit www.acinfinity.com and click contact for our contact information. EMAIL WEB LOCATION support@acinfinity.com www.acinfinity.
MANUAL CODE CTR672110X1 PRODUCT MODEL UPC-A CONTROLLER 67 CTR67A 819137021426 COMPATIBILITY This controller is compatible with AC Infinity fan models that contain EC-motors. An EC-motor fan will have two cords coming out of its motor box for the power and the controller. Note that certain models that previously used DC-motors now contain EC-motors in updated builds. EC Motor - Compatible AC or DC - NOT Compatible Please visit www.acinfinity.
MANUAL INDEX Compatibility .................................................................................. Page 4 Manual Index ................................................................................. Page 5 Product Warning ............................................................................ Page 6 Key Features ................................................................................. Page 7 Product Contents ..........................................................................
PRODUCT WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Ensure your power source conforms to the electrical requirements of this product. 2. Check your local code restrictions for additional safety measures that may be needed for a proper code compliant installation. 3. Read all instructions before installing and using this product. 4.
KEY FEATURES SMART CONTROLLER STEEL FRAME SENSOR PROBE Features automation controls that activate the fan according to temperature, humidity, timer, and schedules. Steel backplate with a black powder coated finish. Includes screws to securely mount the controller to the wall. The corded probe is constructed of stainless steel to ensure precise temperature and humidity readings.
PRODUCT CONTENTS SMART CONTROLLER (x1) WOOD SCREWS (WALL MOUNT) (x2) 8 SENSOR PROBE (x1) WOOD SCREWS (WALL HANG) (x2) MACHINE SCREWS (WALL MOUNT) (x2) WIRE TIE (x1)
POWERING AND SETUP STEP 1 Locate the Molex connector of your fan and plug it into the fan port at the bottom side of the controller. STEP 2 Locate the connector plug of the sensor probe and plug it into the sensor port at the bottom side of the controller. Keep the probe cord away from your HID* grow light ballast's power cord to ensure the controller properly detects climate conditions.
POWERING AND SETUP STEP 3 Position the corded sensor probe and secure it by using the included zip ties and tie mounts. STEP 4 Plug the fan's power cord into a wall outlet. The controller will receive power from the fan to operate.
DAISY CHAIN AND SETUP The fan controller can power up to two compatible fans to share the same programming. The compatible fans do not need to be the same model or part of the same product series. Please see page 4 for compatibility details. The controller receives power from the fans to operate, and only provides programming. Each linked fan will still require its own power source.
PROGRAMMING 1. MODE BUTTON 2. UP/DOWN BUTTONS 3. SETTING BUTTON Cycles through the controller’s available modes: OFF, ON, AUTO (4 triggers), TIMER TO ON, TIMER TO OFF, CYCLE (On and Off), and SCHEDULE (On and Off). Adjusts the value of your current mode. The up button increases and down button decreases the setting. Hold both to reset values to OFF or 0. Cycles through the controller’s available settings: DISPLAY, °F/ °C, CLOCK, CALIB. T°/ H%, and TRANS. T°/ H%. 4. STATUS ICONS 5.
PROGRAMMING CONTROLLER MODES Pressing the mode button will cycle through the controller’s available programming modes: OFF, ON, AUTO (4 triggers), TIMER TO ON, TIMER TO OFF, CYCLE (On and Off), and SCHEDULE (On and Off). OFF MODE Your fan will not run while in this mode. The fan speed set while in this mode establishes the minimum speed in other modes. When the fan is triggered to turn OFF in all other modes, it will instead run at the speed set here.
PROGRAMMING AUTO MODE (LOW TEMPERATURE TRIGGER) Pressing the up or down button sets the low temperature trigger. The fans will activate if the probe’s reading meets or falls below this threshold. Once triggered, the fan will gradually ramp up to the speed set in ON mode. If the probe’s reading rises above this trigger point, the fans will gradually slow down to a stop or at the speed set in OFF mode.
PROGRAMMING AUTO MODE (LOW HUMIDITY TRIGGER) Pressing the up or down button sets the low humidity trigger. The fans will activate if the probe’s reading meets or falls below this threshold. Once triggered, the fan will gradually ramp up to the speed set in ON mode. If the probe’s reading rises above this trigger point, the fans will gradually slow down to a stop or at the speed set in OFF Mode.
PROGRAMMING TIMER TO OFF MODE Pressing the up or down button sets a countdown time. The fans will run at the speed set in ON Mode until the countdown ends. If there is a speed set in OFF Mode, the fans will run at that speed after the end of the countdown. The countdown will begin if no buttons are pressed for 5 seconds. The time left on the countdown is displayed below the current fan speed. Leaving the timer mode while the countdown is running will pause it until you return to this mode.
PROGRAMMING SCHEDULE MODE (ON AND OFF) Sets an on clock-time and an off clock-time schedule for the fan to follow daily. Press the up or down button to first set up an on clock-time to trigger ON mode, then press the mode button to set an off clock-time to trigger OFF mode. Please be sure to set the current clock time under settings. TO ON When the fan is triggered to activate, it will run at the speed set in ON Mode. When the fan is triggered to deactivate, it will run at the speed set in OFF Mode.
PROGRAMMING CONTROLLER SETTINGS Pressing the setting button will cycle through the controller’s available settings: DISPLAY, °F/ °C, CLOCK, CALIB. T°, CALIB. H%, TRANS. T°, and TRANS. H%. DISPLAY SETTING Adjusts the display brightness and auto-dimming. Press the up or down button to cycle through levels 1, 2, 3, A2 and A3; 3 being the highest brightness setting, while 1 is the lowest. In settings 1, 2 and 3, the display will stay at that brightness level and will not automatically dim the display.
PROGRAMMING °F/°C SETTING Changes the displayed units to Fahrenheit or Celsius. Press the up or down button to cycle through F and C. All displayed units will automatically convert when adjusting this setting. CLOCK SETTING Adjusts the current clock time. Press the up or down button to increase or decrease the time. Once you cycle through 12:00 each time, the units will automatically change to AM or PM. The clock time is located at the top right corner of the display.
PROGRAMMING CALIBRATION TEMPERATURE SETTING Adjusts the temperature reading the sensor probe is measuring. Press the up or down button to increase or decrease the data figure in 2°F (or 1°C) increments. The calibration cycle ranges from -8°F to 8°F (or -4°C to 4°C) and will be applied to the sensor probe’s measurements. CALIBRATION HUMIDITY SETTING Adjusts the relative humidity reading the sensor probe is measuring. Press the up or down button to increase or decrease the data figure in 1% increments.
PROGRAMMING TRANSITION TEMPERATURE SETTING Adjusts the transition threshold between the fan speeds in the AUTO Mode temperature triggers. Press the up or down button to cycle through 0°F to 8°F (0°C to 4°C) and set a transition threshold. The fan speed will be set one level above the OFF Mode speed when the sensor temperature first meets or exceeds the high temperature trigger.
PROGRAMMING TRANSITION HUMIDITY SETTING Adjusts the transition threshold between the fan speeds in the AUTO Mode humidity triggers. Press the up or down button to cycle through 0% to 8% to set a transition threshold. The fan speed will be set one level above the OFF Mode speed when the sensor humidity first meets or exceeds the high humidity trigger. For every transition threshold crossed, the fan speed will ramp up by one speed level, up until it reaches the speed set in ON Mode.
PROGRAMMING ALERT ICONS The alert icons are displayed at the top of the screen. Icons may flash when the controller signals an alert to notify you of any triggered function or alarm. ADVANCE PROGRAMMING Displays when an advance program set in the app is active. "ADV." will appear and override the controller if an automation program is in use. HIGH TEMPERATURE ALARM Flashes and beeps with an alert if the temperature rises above the trigger point set in the app.
PROGRAMMING LOW HUMIDITY ALARM Flashes and beeps if the humidity falls below the trigger point set in the app. Continues to flash until the humidity rises above the trigger point. TIMER ALERT Flashes when a countdown has completed for TIMER TO ON, TIMER TO OFF, CYCLE, or SCHEDULE Mode. BLUETOOTH Appears when the physical controller is connected to the app via Bluetooth. CHECK FAN ALERT Flashes when the fan's probe senses interference to its functioning. Check the fan for possible issues.
OTHER SETTINGS FACTORY RESET Holding the mode, up, and down buttons together for 5 seconds will reset your controller and restore factory settings. This HOLD + clears all user parameters in each controller mode and setting. CONTROLLER LOCK Holding the setting button will lock the controller in your current mode. While your controller is locked, no parameters may be adjusted, nor will you be able to switch modes. Holding the power button again will unlock the controller.
DOWNLOAD THE APP THE AC INFINITY APP The AC Infinity app enables you to connect with the next generation of our intelligent controllers, giving you access to advance programs and environmental data. 1 2 Download the AC Infinity app from the App Store or Play Store. Open the AC Infinity app. Follow the instructions in the app to pair your controller with the app. 3 Scan the QR code below or visit our website at www.acinfinity.com for more information on the AC Infinity app.
ADD A DEVICE 1 Connect the fan and probe into your controller. Plug the fan into a wall outlet. 2 Launch the app. Tap the (+) button, then "SMART CONTROLLERS", and select CONTROLLER 67 to begin pairing. Please note: Bluetooth must be enabled on your mobile device before starting the pairing process.
ADD A DEVICE 4 3 Tap DONE button to complete the pairing process. Your controller will appear in your smart device with a unique ID. A-A000A DONE Please note: When pairing the app around multiple controllers, move your mobile device closer to your desired controller.
APP PROGRAMMING 1. MODE BUTTON 2. TEMPERATURE/HUMIDITY 3. SETTINGS Dropdown displays all available controller modes: OFF, ON, AUTO, TIMER TO ON, TIMER TO OFF, CYCLE, and SCHEDULE. Toggles between current temperature and humidity readings. Adjusts app settings including Device Name, Temperature Display, Device Brightness, Fan Speed Transitions, and Calibrations. 4. CONNECTION STATUS 5.
APP PROGRAMMING CONTROLS TAB Contains all controller modes including the OFF, ON, AUTO, TIMER TO ON, TIMER TO OFF, CYCLE and SCHEDULE modes. 1 Tap the paired device to enter the Controls tab, where you can adjust the controller modes. 2 Tap the menu button to access the controller modes. Tap the temperature/humidity button to switch between readings.
APP PROGRAMMING CONTROLS TAB The control wheel displays the temperature/humidity, current settings, and time. 3 Use the wheel hands, (+/-) stepper, or sliders to set your parameters. 4 Use the toggle switch to activate or deactivate any climate triggers.
APP PROGRAMMING ADVANCE PROGRAMMING Creates automated activations, alarms, and push notifications. The adjustable modes in each program include those listed in controls tab. Once an advance program completes its programming (i.e. scheduling), the app will no longer override the controller's onboard settings. Only when the advance program activates will the app override the controller.
APP PROGRAMMING ADVANCE PROGRAMMING - AUTOMATION Each automation can support one mode at a time. To automate multiple modes, you must create additional programs, except for TIMER TO ON and TIMER TO OFF in automation. The app will override the controller while an automation is active. 1 Tap the (+) button to create an automation program. Set a start time and end time using the time picker. Then select your desired mode to trigger. Choose between ON mode, OFF mode, CYCLE mode, or Temperature and Humidity.
APP PROGRAMMING ADVANCE PROGRAMMING - ALARMS Alarms will tell your controller to beep whenever your fan switches on or off as a result of the mode(s) you select in the program. Choose between AUTO, TIMER TO ON, TIMER TO OFF, CYCLE and SCHEDULE modes. Alarm programming will also have a climate points setting in which the alarm will go off when temperature and humidity hits a high or low point. 2 Tap the (+) button to create an alarm program.
APP PROGRAMMING ADVANCE PROGRAMMING - NOTIFICATIONS Notification programs will send push notifications to your mobile device whenever your fan switches on or off as a result of the mode(s) you select in the program. Choose between AUTO, TIMER TO ON, TIMER TO OFF, CYCLE and SCHEDULE modes. Notification programming will also have a climate points setting in which you receive push notifications when temperature and humidity hits a high or low point. 3 Tap the (+) button to create a notification program.
APP PROGRAMMING DATA TAB Logs and stores all temperature and humidity information. Readings are displayed in fluctuation charts and bar graphs and can be viewed in hours, days, weeks, months, and years. Data can be exported as a spreadsheet and sent to other devices by tapping EXPORT CSV DATA. 1 The Fluctuation Charts readout displays the detected temperature or humidity over a given timespan. Swipe left or right to scroll through the readings.
APP PROGRAMMING DATA TAB The fluctuation charts and bar graphs allow you to see trends in temperature and humidity and enable you to make the necessary adjustments to your space. Tap on any point in the charts and graphs to see detailed information on the picket. 2 Bar Graphs - This readout displays how often a detected temperature or humidity point occurs over a given timespan. The minimum and maximum readings of the given timespan are displayed at the top of the graph.
APP PROGRAMMING HISTORY LOG Logs all advance programming notifications and controller activity. Entries can be filtered by controller functions and programming including triggers, timers, cycles, schedules, automation, alarms, and notifications. 1 Swipe up and down to scroll through the history log. 38 2 Tap SHOW FILTERS to reveal activity options. Unchecked functions will filter them from the log.
APP SETTINGS SETTINGS Tap the gear icon to access the settings. Sets all controller-related parameters including Device Name, Temperature Display, Screen Brightness, Transitions, and Calibrations. Tap CONFIRM to save your settings. Tapping CANCEL will leave the settings menu without saving changes. Tapping DELETE DEVICE will unpair your controller from the app. DEVICE NAME Supports a maximum of 20 characters. TEMPERATURE DISPLAY Toggles between Celsius and Fahrenheit scales.
CONTROLLER 67 FAQ Q: Where is the best place to position the sensor probe? A: Place the sensor probe as close as possible to the hottest or most humid spot in your space. Q: Do I need to remove the plastic cap from the probe? A: Yes. You will need to remove the plastic cap so the probe can accurately read climate conditions. Q: Can I connect different sized fans to the same controller? A: Please refer to page 10 for details on daisy chaining fans together.
AC INFINITY PRODUCTS Advance Grow Tents The CLOUDLAB series is a line of grow tents designed to create ideal growing conditions and facilitate indoor plant cultivation year-round. Features 2000D thick oxford canvas lined with inner diamond patterned mylar that maximizes grow light luminosity, and a reinforced frame with 150 lb. weight capacity. Includes a mounting plate to install your AC Infinity controller onto.
WARRANTY This warranty program is our commitment to you, the product sold by AC Infinity will be free from defects in manufacturing for a period of two years from the date of purchase. If a product is found to have a defect in material or workmanship, we will take the appropriate actions defined in this warranty to resolve any issues. The warranty program applies to any order, purchase, receipt, or use of any products sold by AC Infinity or our authorized dealerships.
FCC Warning This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
www.acinfinity.