PROGRAMMING
BUFFER TEMPERATURE SETTING
The buffer figure will create a trigger-off point 
below your set trigger point to prevent your 
device from shutting off too quickly. Press the 
up or down button to cycle through buffer range 
from 0°F to 8°F (or 0°C to 4°C).
In high temperature triggers, your device will 
turn on, only turning off when the temperature 
falls below your buffer setting.
In low temperature triggers, your device will turn 
on, only turning off when the temperature rises 
above your set buffer setting.
EXAMPLE
In this example, your High Temperature Trigger 
is set at 89°F and your Temperature Buffer is 
set at 6°F. Your device will trigger on when it 
meets or rises above 89°F, and only trigger 
off when it falls below 83°F. The 83°F figure 
is obtained by taking your High Temperature 
Trigger of 89°F and subtracting your 
Temperature Buffer of 6°F.
89
83