User manual
– 28 – – 29 –
Technical data
• Power supply DC 3 V Lithium Battery (built-in)
• Smoke detection photoelectric reection
• Visual operating display LED ashes once per second
• Electric consumption < 8 μA (standby) || 50 mA (alarm)
• Operating temperature 0° to 40° C
• Air humidity 10 % to 93 % (non-condensing)
• Sound pressure > 85 dB (A)@3 m
• Alarm mute mode 10 minutes
• Detection range max. 40 m² within a single room
• Installation location ceiling (internal rooms only)
In order to avoid injuries, this device must be reliably fixed to the ceiling
as per installation instructions.
Functions and technical features
• The smoke alarm does not detect gases, vapours, heat and fire/flames!
• It is possible that people with limited hearing may not hear the alarm!
For such cases special alarms with optical signalling are available.
• Especially high electromagnetic radiation may affect unit operation. Therefore, do
not install the alarm near devices which emit electromagnetic radiation or close
to magnets.
Safety information Technical data