operation manual

– 26 –
– 27 –
Replacing the battery
If the battery is low, the smoke detector beeps once every 43 seconds (for up
to 30 days) to remind you to replace the battery.
You must change this battery when you hear this signal.
Loosen the detector from the detector base by turning it in an anticlockwise
direction, remove the old battery and insert a new battery into the detector with
the correct polarity (see diagram 1).
Even so, the smoke detector remains functional in this condition.
You must test the smoke detector each time you change the battery.
Carry out the test as detailed above.
Note
To ensure a long service life and reliable operation, we recommend using
the following high-quality batteries:
• EVE CR123A, PAIRDEER CR123A
Alarms and error signals
When the alarm threshold is exceeded, a loud alarm sounds.
The alarm continues sounding as long as there is smoke in the detection chamber.
The alarm is only switched off when there is no more smoke in the detection
chamber.
What to do if there is a false alarm?
A false alarm can occur due to very high air humidity, the build-up of smoke whilst
cooking or a large build-up of dust, or smallest insects for example.
If the alarm sounds, first get yourself to safety. If you are certain that it is a false
alarm, you can switch the alarm mute for about 9 minutes by pressing the
test/stop button.
The smoke detector will switch off automatically once the smoke particles have
left the smoke chamber inside the detector.
Putting into operation
GB
RWM90_MA_DEGBFRNLIT_103x103_AJ.indd 27 30.09.19 13:20