PT Series Pressure Transmitters User Manual ABUS TECHNOLOGIES INC.
PT WARNING v This manual should be passed on to the end user. v The contents of this manual are subject to change without prior notice. v All rights reserved. v ABUS gives no warranty of any kind with regard to this manual, including, but not limited to, fitness for a particular purpose. v If any question arises or errors are found, or if any information is missing from this manual, please inform your supplier or inform at info@abustek.com.
PT . CATALOGUE Contents Page No. 4 4 1. Introduction Applications 2. Presentation 1. Features 2. Technical Parameters 4 4 5 3. Dimensions 5 4. Ordering Details 6 5. Connections 7 8 9 7 9 9 10 10 10 Output Characteristics 6. Installation Recommendation 7. Operation 1. Zero and Span Adjustment Procedure 2. Example for Usage 8. Maintenance Troubleshooting 9. Safety Precautions 11 10. Warranty 11 ABUS TECHNOLOGIES INC.
PT 1. INTRODUCTION PT Series of Pressure Transmitters are precision engineered to fit most industrial pressure measurement applications. The compact, rugged design make these instruments suitable for applications including hydraulics and pneumatics, vacuum, test equipment, liquid level measurement, pressure control, compressor control, pump protection and numerous other processing and control operations.
PT 2.2 Technical Parameters Accuracy: ±0.25%FS (BFSL) ±0.5%FS (limit point calibration) Ranges: Absolute: 0…1 to 0…50 bar, 0…15 to 0…750 psi Vacuum: (-1)… bar, (-15)…0 psi Gauge: 0…100mB to 0…1000 bar, 0…1.5 to 0…15000 psi Output: 0...5 V, 0...10 V, 0.5...4.5 V, 4...20 mA (Customized On request) Power Supply: 24Vdc (10~36Vdc) Maximum Pressure: 1.5 x F.S. Adjustability Zero / Span: ± 10 % using potentiometers inside.
PT 4.
PT 5. CONNECTIONS WIRE SIGNAL OUTPUT EXCITATION 2-wire 4 ~ 20mA 12 ~ 36 Vdc 3-wire 0 ~ 10 Vdc 12 ~ 18 Vdc ABUS TECHNOLOGIES INC.
PT Output Characteristics (FOR PT20-12XXXX Pressure Transmitter) A B C D C D ABUS TECHNOLOGIES INC.
PT 6. INSTALLATION Recommendation 1. Please confirm the configuration for Pressure Transmitter i.e. 2- wire, 3-wire and accordingly follow the wiring procedure. Ensure that the excitation voltage is supplied to the correct points and is with in the specified limits for that particular configuration as mentioned in the table above. 2. When installed, ensure that the transmitter is not subjected to the excessive sources, and it should be considered before installing the Transmitter.
PT 7.2 Example for Usage 8. MAINTENANCE Troubleshooting S. No. SPECIFICATIONS ELIMINATE 1 No output • • Check the wiring configuration. Check the input power supply. 2 No variation in output • • Check for leakage at pressure port / point. Check the span set of Indicating Instrument. 3 Pressure not holding at constant input pressure. • • Check for leakage pressure point. Check for the connections ensure they are properly tightened. ABUS TECHNOLOGIES INC.
PT 9. SAFETY PRECAUTIONS 1. The unit should be powered for 15 minutes before use. 2. Use in ambient temperature of 0-60˚C. 3. Avoid vibrations, shock, excessive dust, corrosive chemical materials or gaseous environment. 4. Input wire should not be too long. If measured signal have to be far away from the unit, please use 2core shielded cable. 5. Use this instrument in the scope of its specifications, otherwise fire or malfunctions may result. 6.