Specifications

Device Configuration
IM/265/7/9/ADD/FF-EN_01 Connection to FOUNDATION Fieldbus 27
Idx Name Byte PC Description
1 R/W Grant 14 GRANT_DENY
1 R/W Deny
15 HARD_TYPES 2 R The type of Hardware available as channel numbers. For the
2600T – 265 / 267 / 269 this is limited to Scalar Inputs
(i.e. Analog Input).
16 RESTART 1 R/W Allows a manual restart to be initiated. More restart are
possible, they are:
1. Run - Normal state when running
2. Restart Resource
3. Restart with Default - Set the parameters to INITIAL
VALUES.
4. Restart Processor - perform a warm start-up
5. Reset to Factory Sensor Trimming - Re-load the original
Factory Calibration
17 FEATURES 2 R Used to show supported resource block options.
18 FEATURES_SEL 2 R/W Used to select resource block options.
19 CYCLE_TYPE 2 R Identifies the block execution methods for this resource.
20 CYCLE_SEL 2 R/W Used to select the block execution methods for this resource.
The 2600T – 265 / 267 / 269 supports the following:
- Scheduled: Blocks are executed depending by the function
block schedule.
- Block execution: A block may be executed by linking to
another block completion.
21 MIN_CYCLE_T 4 R Time duration of the shorted cycle interval of which the
resource is capable.
22 MEMORY_SIZE 2 R Available configuration memory in the empty resource. To be
checked before attempting a download.
23 NV_CYCLE_TIME 4 R Minimum time interval for writing copies of NV parameters to
non-volatile memory. Zero means it will be never automatically
copied.
24 FREE_SPACE 4 R Percent of memory available for further configuration. Zero in a
preconfigured device.
25 FREE_TIME 4 R Percent of the block processing time that is free to process
additional blocks.