FUMK50020 Secvest mini wireless opening detector GB 14 Installation instructions Mini wireless opening detector Version 1.
- 16 -
Contents Preface........................................................................... - 18 Battery warning information ........................................ - 19 Safety information ........................................................ - 19 Scope of delivery .......................................................... - 20 Technical data ............................................................... - 20 Start-up ..........................................................................
Preface Dear customer, Thank you for purchasing this mini wireless opening detector. This device is built with state-of-the-art technology and complies with current domestic and European regulations. Conformity has been proven, and all related certifications are available from the manufacturer on request (www.abus.com). To guarantee safe operation, it is essential that you observe these installation instructions. If you have any questions, please contact your specialist dealer.
Battery warning information The device is supplied with direct current from a 3.6 V lithium battery. To guarantee a long lifespan and avoid fire and injury, please note the following: Do not dispose of the battery in domestic waste. The battery may not be directly exposed to heat or sunlight. The battery may not be burned. The battery may not come into contact with water. The battery may not be dismantled, pierced or otherwise damaged. The battery contacts may not be short-circuited.
Scope of delivery (1.) Motherboard housing (2.) Backplate (3.) Dust cover (4.) Magnet holder attachment (5.) 7 mm plate (6.) Magnet bracket (7.) Fixing screws (8.) Battery Technical data Power supply: 3.6 V lithium-thionyl chloride Battery type: SAFT LS1425 (please use this battery type only) Power consumption: 0.03 A Battery life: up to 36 months Radio frequency: 868.6625 MHz/FM Housing material: ABS Dimensions (LxWxH): 33 x 89 x 29 mm Weight: approx.
Start-up Insert the battery into the wireless opening detector. IMPORTAN T Ensure that the polarity is correct. Assign the detector in zones See the relevant device information. Press the tamper switch (anti-removal wall contact), until the receiver has received the signal, indicated by a beep.
Range The range is dependent on environmental factors. Check whether the detector is communicating properly with the alarm control panel prior to assembly. When assembling the detector: do not assemble it on or near metal surfaces. keep it at least 1 m from gas, water or power lines. do not assemble it near electronic equipment such computers, photocopiers or other transmitters and interferences.
For window/door frames with a rabbet depth of less than 19 mm and sufficient space, we recommend installing the wireless opening detector on the window/door frame. (Reverse installation is also possible in this instance, however.) For window/door frames with a rabbet depth of more than 19 mm, the wireless opening detector must be installed on the leaf of the window/door using the 7 mm magnet bracket plate.
Installation The following section describes how to install the wireless opening detector on the leaf of the window or door. (Installation on a window or door frame follows the same procedure.) Position and screw on the backplate The holes for the fixing screws must be aligned in the direction of the wall (and not aligned with the centre of the door/window). Distance from the door/window edge: 10 mm 10 mm (Figure shows window with DIN on right; installation with DIN on left follows the same procedure.
Attach dust cover Attach the dust cover (so that the ABUS logo is legible) and press this into place. max. 3 mm Fit magnet bracket If the rabbet depth is no more than 19 mm, the magnet bracket can be fitted without the 7 mm base. Side-on distance between the magnet bracket and window leaf max.
For rabbet heights of up to 20 mm, you will need to use the 7 mm magnet bracket base. (The base can improve the efficacy of the magnetic contact.) Side-on distance to the window leaf also max. 3 mm.
Press the magnet bracket including the magnet into the fitted magnet holder attachment. Position the magnet in the magnet bracket as shown in the adjacent illustration. Changing the battery Before changing the battery, set the alarm system to installer mode or hide the respective zone (see corresponding device information).