User manual
Scope of delivery | Technical data
12
Scope of delivery
ABUS CO alarm
Mounting material
9 V alkaline block battery
User guide
Technical data
Power supply
DC 9 V alkaline block battery
- Duracell 9 V Alkaline (6LR61, MN1604)
- GP 9 V Alkaline (6F22, 1604S)
Trigger sensitivity
Conforms to EN 50291-1:2010 + A1:2012
CO
concentration
No alarm
within
Alarm at
the latest
after
30 ppm
120 min
-
50 ppm
60 min
90 min
100 ppm
10 min
40 min
300 ppm
-
3 min