User guide
50
13. Technical data
Security level: 2 EN 50131-1 and -3 :2007-04
Environment class: II, EN50131-1 or EN50130-5
Operating temperature: -10 °C to +55 °C, EN50130-5 Clause 8 (+55 °C) and
Clause 10 (-10 °C), with average relative humidity 75%, non-condensing
Power supply: 10-14 V DC, 12 V DC nominal, device protected by pole protection diode
Power consumption: max. 300 mA
Emergency power supply: None
Number of channels: 8 device channels
8 PIN/proximity chip key channels
Display: 10 LEDs, visible from the outside when housing is closed.
8 blue LEDs for channels and programming
1 red LED for faults
1 green LED to display the power supply
Outputs: 6 semi-conductor relays with potential-free contacts (can be set to NO or NC) for
Tamper
Panic
Activation command
Internal activation command
Low battery
Supervision or Jamming
Maximum switching power
U DC max = 48 V DC
I DC max = 500 mA
U AC max = 30 V AC rms
I AC max = 350 mA rms
Forward resistance of <=2 Ω
Lock resistance >=50 MΩ (at a maximum creepage of 1 µA at 50 V)
Inputs: 10, voltage-controlled, for
Alarm centre activated
Alarm centre internally activated
Not ready for activation or general fault
Flash
Siren in case of alarm
Setup mode
Siren in case of fire
Input time info beep
Output time info beep
Error during output time info beep