Manual

7
1. Main features
8 programmable zones
tamper monitoring
duplex-antenna technology
simple connection using 4-wire BUS
compatible to TERXON M / MX
868MHz FM security frequency
2. Main features
3. Installation
1. Open the housing of the radio expansion.
2. Release the 3 screws and remove the PCB from the
rear wall of the unit.
3. Use the rear of the radio expansion unit to draw the
boreholes at the required assembly location. Bore the
appropriate holes and insert the correct dowel pins into
then.
4. Insert the cable of the 4-wire BUS through the opening
on the rear of the module.
1 Error LED (Fail)
2 OK LED (Pass)
3 Detector
4 Display
5 Select button
6 Delete button
7 Antenna
8 Tamper switch
9 Radio PCB
10 Learn sensor
11 Supervision jumper
12 Jamming jumper(radio
interference)
13 Addressing jumper
14 BUS Connection
15 Cable Entry