User manual
37
UK
Behaviour of Additional Switch Output 1
(151 nn )
Menu item Setting Meaning
151
00 Not used
01 Fire to follow
02 Panic to follow
03 Burglary to follow
04 Active/inactive to follow
05 Alarm cancellation
06 Technical alarm
11 Network fault
12 Sabotage to follow
13 Active to follow
14 Inactive to follow
15 Zone locked
16 Emergency alarm to
follow
17 Keybox
18 Anti-mask
19 Fire alarm
30 Active pulse 1
31 Active pulse 2
32 Active pulse 3
33 Active pulse 4
34 Inactive pulse 1
35 Inactive pulse 2
36 Inactive pulse 3
37 Inactive pulse 4
Behaviour of Additional Switch Output 2
(152 nn )
Menu item Setting Meaning
152
See setting
for switch output 1
Behaviour of Additional Switch Output 3
(153 nn )
Menu item Setting Meaning
153
See setting
for switch output 1
Behaviour of Additional Switch Output 4
(154 nn )
Menu item Setting Meaning
154
See setting
for switch output 1
Behaviour of Additional Switch Output 5
(155 nn )
Menu item Setting Meaning
155
See setting
for switch output 1
Behaviour of Additional Switch Output 6
(156 nn )
Menu item Setting Meaning
156
See setting
for switch output 1
Behaviour of Additional Switch Output 7
(157 nn )
Menu item Setting Meaning
157
See setting
for switch output 1
Behaviour of Additional Switch Output 8
(158 nn )
Menu item Setting Meaning
158
See setting
for switch output 1
Inversion of additional switch outputs
(159 n )
Menu item Setting Meaning
159
0 Not inverted
(+ve removed)
1 Inverted
(+ve applied)
Duration of active pulse 1 2 3 4
(170 n n n n )
Menu item Setting Meaning
170
00 Latched output
01 – 12 Pulse duration in
seconds
Switch output active stable
(171 n n n n )
Menu item Setting Meaning
171
A B C D
Activate switch output
for active area