Technical Specifications

KP Building Products I-span Wall panel Specifications
Page 2 of 2 September 2017
2.01 Accessories:
A. Accessories shall be consistent with the shape, size and properties
as shown in the drawing and as required for complete installation.
Accessories shall be produced from the same compound materials
and with comparable properties as the panel.
2.02 Fasteners:
A. Galvanized nails or other corrosion-resistant fasteners, with a
minimum 5/16 in. diameter head and minimum in. diameter
shank.
PART 3 – EXECUTION
3.01 Examination
A. Confirm that all critical dimensions are as specified in the drawings.
B. Commencement of I-span panel installation implies acceptance of
the substrate as suitable to accept I-span panel and accessories.
3.02 Preparation
A. Any substrate flaws or defects must be repaired and free from
obstructions before the I-span panel is applied.
3.03 Installation
A. I-span panel is installed with fasteners into solid backing a
maximum of 24 in. on center. The fasteners must be corrosion
resistant with a minimum 5/16 in. diameter head and minimum
in. diameter shank.
B. Fasteners must penetrate solid backing a minimum of 7/8 in.
C. All panels should be allowed to slide free after fastening to allow for
expansion and contraction.
3.04 Field Quality Control
A. After installation of I-span panel check entire surface for obvious
flaws or defects. Replace and repair any problem areas.
3.05 Cleaning
A. After the I-span panel has been applied, clean as necessary to
remove all fingerprints and soiled areas.
B. Clean and remove all scrap, packaging and unused materials
resulting from the installation of the products.
All KP BUILDING PRODUCTS I-span panels and accessories are
backed by Limited Lifetime Warranty.