User's Manual

1-7
Siemens 9751 9006i DTMF Integration Guide
OL-1747-02
Chapter 1 Siemens 9751 9006i DTMF Integration
Programming the Phone System
All MWIs on subscriber extensions are turned off when the phone system restarts.
To reset MWIs, run the phone system Message-Waiting Refresh utility on menu
13.5.
If you use the broken dial tone for MWIs, subscribers can confuse the MWIs with
the stutter dial tone that the phone system uses for another purpose.
Step 5 Repeat Step 4 for each remaining SLMA voice messaging port that sets MWIs.
Step 6 Use the ADDHUNT command to create a hunt group for the answering voice
messaging ports. All subscriber phones will use this hunt group to reach
Cisco Unity. The hunt group must have the following parameters while the
remaining parameters keep their default values.
HTLNIDX (leave field blank)
DEVFUNC ANATE
MSGWLMP N
SPECL (leave field blank)
DIAL DTMF
DLIDX (leave field blank)
INS Y
SPDC1 (leave field blank)
SPDC2 (leave field blank)
SPDI (leave field blank)
LCROSD1 (leave field blank)
LCROSD2 (leave field blank)
LCRCOSV1 (leave field blank)
LCRCOSV2 (leave field blank)
FAXSERV (leave field blank)
DTS N
AV D N
CDIDX (leave field blank)
Table 1-3 ADDSCSU Parameter Settings for MWI Ports
Parameter Required Setting