User's Manual
1-5
Siemens 9751 9006i DTMF Integration Guide
OL-1747-02
Chapter 1 Siemens 9751 9006i DTMF Integration
Programming the Phone System
To program the phone system for analog ports
Step 1 Use the ADDDPLN command to create an extension for each voice messaging
port and for the hunt group pilot number. Each extension must have the following
parameters set while the remaining parameters keep their default values.
Step 2 Use the ADDSCSU command to create the first SLMA voice messaging port that
answers calls. Each voice messaging port answering calls must have the following
parameters while the remaining parameters keep their default values.
Table 1-1 ADDDPLN Parameter Settings
Parameter Required Setting
DGTS
• <first extension>&&<last extension> (for voice
messaging port numbers)
• <hunt group pilot number>
DPLN 0
CPS (leave field blank)
DAR
• STN (for voice messaging port numbers)
• HUNT (for hunt group pilot number)
CHECK N
Table 1-2 ADDSCSU Parameter Settings for Answering Ports
Parameter Required Setting
STNO <the extension number>
PEN <the port equipment number>
DPLN 0
ITR 0
COS1 <a standard class of service>
COS2 <a standard class of service>
COSX (leave field blank)
PUBSCR <the PSTN prefix plus the extension number>