User's Manual
Chapter 1 Siemens 9751 9006i DTMF Integration
Integration Overview
1-2
Siemens 9751 9006i DTMF Integration Guide
OL-1747-02
Requirements
The Siemens 9751 9006i integration supports configurations of the following
components:
Phone System
• Siemens 9751 9006i
(Release 9005 is not supported.)
• Software version 9006.1 or 9006.2
For version 9006.1, these patches are required:
–
S50245 - Source code corrected at Release 6.1 bind KV18
(corrects the information displayed for calls the automated attendant
forwards)
–
S50533 - Incorporated in Patch Package “A” bind KV19
(allows attendant console to send DRMF internally)
–
S50551 - Incorporated in Patch Package “B” bind KV19
(provides 600 ms of disconnect tone on the EXTVCML ports)
–
S50655 - Incorporated in Patch Package “G” bind KV19
(allows supervised transfers on EXTVCML ports)
–
S50751 - Incorporated in Patch Package “J” bind KV19
(allow the MB key to be associated with the REPDIAL key)
When a change is made to a subscriber extension, this patch turns off the
MWI.
–
S50775 - Incorporated in Patch Package “K” bind KV 19
(corrects TDM/crosstalk problems)
• A SLMA interface channel for each voice messaging port
• The voice messaging ports in the phone system connected to the voice cards
in the Cisco Unity server
• The phone system ready for the integration, as described in the
documentation for the phone system