Instructions

17
OPERATION
Wallbox
Status Display
Stand by LED
flashes
LED
off
Electric vehicle detected LED
on
LED
off
Electric vehicle charging LED
off
LED
on
Charging completed at the vehicle LED
off
LED
flashes
Stand by LED
flashes
LED
off
7.3 Normal charging cycle
The charging cycle corresponds to IEC 61851-1 Mode 3
1 Service procider switch
Allows the recharge process to be interrupted by turning the switch
located on the right hand side of the control panel to the „0 OFF“
position. To start the recharge process, the switch must be in the
„1 ON“ position. Charging (normal & eco) can be started only in the
position „1 ON“.
2 Lockable circuit breaker cover
In order to prevent tampering, the charging station has a lockable
controls cover (not vandalism-proof). The wallbox is supplied with
two keys. If lost, please contact your service provider.
3 Drilling template for wall mounting
Schematic drawing No. 4 printed in a size DIN A2 sheet serves
as a template for determining the positions of the holes for wall
mounting. The mounting surface must measure at least 250x360
mm (10"x15")! Download: www.abl-sursum.com