Description
The EVCC module controls the power-supply of an electric vehicle (EV) while charging at a supply equipment
(EVSE). The communication between EV and EVSE complies with IEC 61851-1 Mode 3.
Potential-free switching contacts are used for load control (EV power-supply), locking-device (for type 2 socket-
outlet) and external ventilation.
Two external LEDs can be connected without additional resistors and indicate the present system status. Default
and available charging current can be set via the RS485 serial interface. The available charging current can be
changed while charging, limited by the default current and the rated current of the charging cable (type 2 socket-
outlet only).
Authorization of the charging process and monitoring of the locking mechanism of the socket outlet are controlled
by external switches directly connected to the module.
Using the RS485-interface several EVCC can be connected as network with an individual address assigned to
each module.
Technical data
Rated voltage 230V @ 50Hz or 115V @ 60Hz
Rated current 20mA
eff
(230V) or 40mA
eff
(115V)
Ambient temperature (storage) -30 … 85°C
Ambient temperature (operation) -25 … 50°C
Relative humidity 10 … 90% (no condensation)
Protection rating II
Overvoltage category III
IP rating IP20
Degree of pollution 2
Housing 4HP, 35mm mounting rail
Connections Screw terminals, max. 2.5mm², max. 0.6 Nm
Rated power of relay contacts
230V
eff
3A resistive (cosΦ =1)
Relay contacts must be protected against overload
LED output switching current Max. 10mA
Fuse 2AT internal, primary, not replaceable
Serial interface RS485, 38400Bd, 8 data bits, 1 stop bit, no parity
No internal termination; use 120Ω-resistor to terminate both
ends of network!
WARNING:
No galvanic isolation
Terminal M is internally connected to FE