User manual
EVCC – Installation and User Guide
Page 13
Dok. Nr. 03 0009 01 D
Communication
Commands must end with <CR><LF>.
Answers sent by the module end with <CR><LF>.
n module address (address 0 contacts all modules within the network!)
M in state MANUAL available only
A in state A available only
Function PC Module
ModulePC Parameter xxxx
Reset AM !n 00 1111
Get firmware AM !n 01 >n 01 Vx.y Vx.y Firmware Rev.
Get status !n 02 >n 02 xxxx 0000 State A
0004 State B2
0005 State C
0006 State D
0009 State B’
0013 State B1
0017 State A’
0033 Error CS
0035 Error EV
0037 Error locker
0039 Error ventilation
0255 State MANUAL
Switch to MANUAL A !n 03 >n 03
Status output !n 04 >n 04 xxxx xxxx is sum of
0000 all off
0001 X1 on
0002 X2 on
0004 K1 on
0008 K2 on
0016 K3 on
0032 CP +12V on
0064 CP -12V on
Set output
M !n 05 xxxx >n 05
Clear output M !n 06 xxxx >n 06
0001 X1
0002 X2
0004 K1
0008 K2
0016 K3
0032 CP +12V
0064 CP -12V
Get ADC-value pos. U
CP
!n 07 >n 07 xxxx
Get ADC-value neg. U
CP
!n 08 >n 08 xxxx
U = 0.017 ⋅ xxxx [V]
Get ADC-value U
CS
!n 09 >n 09 xxxx 0000….1023
Get input !n 10 >n 10 xxxx 0000 E1 & E2 open
0001 E1 closed
0002 E2 closed
0003 E1 & E2 open
Get present PWM
(present charging current)
!n 11 >n 11 xxxx PWM in 0.1%-steps
I
LADEN
= PWM⋅0.6A resp. (PWM-
64)⋅2.5A