Charging procedure (Firmware V2.3 and later)
Procedure of charging complies with IEC 61851-1 Ed. 2 Mode 3: A B1 B2 C/D B’ A
State X1 X2 K1 K2 K3 Description
A
Off Off Off
Module waiting for connection of an EV
X1 flashing each 5s
CP switched on (duty cycle 100%)
B1
Off Off Off
Connected EV detected
CP switched on (duty cycle 100%)
B2
Off Off Off
Charging enabled (E1)
Available current (limited by default-current and
rated current of charging cable) transmitted from
module to EV by corresponding duty cycle via CP
Module waiting for request for charging by EV
C
On Off On
Request for charging without ventilation by EV
D
On On On
Request for charging with external ventilation by EV
B’
Off Off Off
Charging stopped by EV
Available current transmitted from module to EV by
corresponding duty cycle via CP
Module waiting for disconnection of cable or new
request for charging by EV
E
Off Off Off
Error
CP off (duty cycle 0%)
Remark:
Switch to A automatically after 30s
A’
Off Off Off
CP off (duty cycle 0%)
X1 flashing each 2,5s
No detection of EV
Remark:
Switch to A’/Leaving A’ only via RS485-command
Remark:
Disconnection of EV or interruption of PE-line between EV and module during charging leads to status A
immediately.