User manual
EVCC – Installation and User Guide
Page 11
Dok. Nr. 03 0009 01 D
Factory settings
Network address 0
Default charging current 16A
Ventilation no external ventilation connected (marker „ventilation“ set)
Indication firmware
Immediately after power-on X1 and X2 indicate present firmware Vx.y by flashing (X1 ⇒ x, X2 ⇒ y)
Load management
Available charging current may be modified during charging via RS485; current is limited by default-current and
rated current of charging cable.
After reset available current is set to default-current
Indication of error (Firmware V2.3 and later)
The different types of error (charging state E) are indicated by individual flash-sequences of connected LEDs.
Error Flash-sequence Possible root cause
ERRFAN
EV requested external ventilation for charging,
although there is no external ventilation
available
ERREV
Short-circuit of PE and CP
Internal error of EV socket-inlet
ERRSHT
Malfunction of locking device of type 2 socket-
outlet
ERRCS
Malfunction of CS-connection
Resistance between FE and CS too high
X2
X1
X2
X2
X1
X1
X2
X1
X2
X2
X2
X2
X1
X1
X1
X1