User Guide
Chapter 4
SR7-8X
4-22
Keyboard PowerOn Function:
Four options are available: Disabled ( Any Key ( Specific Key ( Password. The default setting is
Disabled. This item let you set the key for keypad wakeup. After you set the key or password, any event
affecting keypad will awaken a system that has powered down.
Resume by USB:
Two options are available: Disabled or Enabled. The default setting is Disabled. When set to Enabled,
any event occurring at a USB port will awaken a system that has powered down.
Wake Up by PS2 Mouse:
Two options are available: Disabled or Enabled. The default setting is Disabled. When set to Enabled,
any event affecting PS/2 mouse (through the PCI PME internal pin) will awaken a system that has
powered down.
Wake Up by PME:
Two options are available: Disabled or Enabled. The default setting is Disabled. When set to Enabled,
any event affecting LAN card (through the PCI PME internal pin) will awaken a system that has powered
down.
Wake Up by Modem Ring:
Two options are available: Disabled or Enabled. The default setting is Disabled. When set to Enabled,
any event affecting the modem (external modem) ring will awaken a system that has powered down.
Wake Up by RTC Alarm:
Two options are available: Disabled or Enabled. The default setting is Disabled. When set to Enabled,
you can set the date, hour, minute and second alarm at which the RTC (real-time clock) alarm awakens
the system from Suspend mode. The enable items will appear white in color and disabled items will show
a blue green color.
RTC Alarm Date:
You can select the date from 01 ~ 31, or Every Day. The default setting is Everyday. This field is not
available to enter when the “Resume by RTC Alarm” field is Disabled.
RTC Alarm Hour:
You can select the hour from 00 ~ 23, which means the hour of 00 to hour of 24. This field is not
available to enter when the “Resume by RTC Alarm” field is set to Disabled.
RTC Alarm Minute:
You can select the minute from 00 ~ 59, which means the minute of 00 to minute of 60. This field is
not available to enter when the “Resume by RTC Alarm” field is set to Disabled.
RTC Alarm Second:
You can select the second from 00 ~ 59, which means the second of 00 to second of 60. This field is
not available to enter when the “Resume by RTC Alarm” field is set to Disabled.