Owner Manual

Table Of Contents
5
Modes Explanation
AUTO MODE
If ambient humidity 47%. Then the compressor stops, the fan stops 30
seconds later.
If ambient humidity 53% fan running at high speed for 3 seconds,
compressor start working.
CNT/DRY CLOTHES MODE
In CNT mode, the dehumidifier continuously runs at high fan speed until the
ambient humidity reaches 20%. It is suitable for clothes drying or conditions
that require continuous dehumidification.
SLEEP MODE
If ambient humidity 47%. Then the compressor stops, the fan stops 30
seconds later.
If ambient humidity 53% fan running at low speed for 3 seconds,
compressor start working.
Water Tank Full Alarm
Water Tank Indicator
When the tank is full for 5 seconds, it sets the alarm. The water tank indicator
turns red and the unit buzzes for 15 times.
Clear the alarm
When the buzz is on, press the POWER button to stop it. The compressor,
fan and ionizer generator shut down and all the functions freeze until the tank
is emptied and back in right position.