TROUBLE SHOOTING
1. FUNCTIONING TEMP.
41 Ambient Temp. 95
When the ambient temp is lower or higher than the functioning temp, the
dehumidifier stops operation.
When 41 Ambient temp. 60.8, the compressor automatically defrosts
at intervals; during defrosting, the compressor stops and the fan keeps
running.
2. BEFORE CALLING FOR SERVICE
Before contacting professional service, please review the trouble shooting list
that includes common occurrences that are not the result of a defect in
workmanship or materials.
Problem Possible Cause Solution
Not working
No power supply Connect to a functioning outlet and switch on
Water Full Indication Flashes
Drain water tank and reset it, or re-position the
water tank to proper place
Room temperature ˂ 41, or ˃ 95
Self-Protection de
signed to protect the unit.
The unit cannot work under such temperature
Bad functioning
Is the air filter clogged? Clean the air filter as instructed
Is the intake duct or discharge duct
obstructed?
Remove the obstruction from the discharge
duct or intake duct.
No air intake Is the filter clogged? Wash the filter
Loud noise
when running
Is the machine put in the flat place? Put the machine on the flat ground
Is the filter clogged? Wash the filter
E2 Humidity sensor problem Change a sensor
LO Environmental humidity is below 35%
The dehumidifier shuts down for self-
protection
HI Environmental humidity is above 95%
CL
Low temperature protection, the
environmental temperature41
CH
High temperature protection, the
environmental temperature95