Use Manual
Table Of Contents
- Table of contents
- Read me first
- Section 1: Use or function
- Section 2: Installation procedures and special requirements
- Section 3: Principles of operation
- Section 4: Performance characteristics and specifications
- Section 5: Operating instructions
- Section 6: Operational precautions and limitations
- Section 7: Hazards
- Section 8: Service, maintenance, and diagnostics
- Section 9: Troubleshooting
- Appendix A: Alinity ci-series SAL
- Design and function
- Technical data
- Sample Access Line operation
- Buttons
- Start screen
- Power on the Sample Access Line
- Place the Sample Access Line online
- Place the Sample Access Line offline
- Pause the Sample Access Line
- Deactivate pause mode
- Restart the Sample Access Line
- Main menu screen element descriptions
- Login screen
- Access the Login screen
- Information screen element descriptions
- Access the Information screen
- Access the Configuration screen
- Error message screen
- Acknowledge an error message
- Acknowledge a message
- Weekly cleaning procedure
- Error messages
- Communication and software update error messages (0-10000)
- Module component error messages (20000-29999)
- Message code: 20105
- Message code: 20200
- Message code: 20201
- Message code: 20202
- Message code: 20203
- Message code: 20204
- Message code: 20205
- Message code: 20206
- Message code: 20207
- Message code: 20209
- Message code: 20210
- Message code: 20211
- Message code: 20901
- Message code: 20902
- Message code: 20910
- Message code: 20911
- Message code: 20912
- Archive error messages (21300-21468)
- Message code: 22501
- Message code: 22502
- Message code: 22550
- Message code: 22600
- Message code: 22601
- Message code: 22602
- Message code: 22603
- Message code: 22604
- Message code: 22605
- Message code: 22606
- Message code: 22607
- Message code: 22608
- Display error messages (23000-23017)
- Message code: 27000
- Error message on the touchscreen user interface
- CAR with sample at AccessPoint, in traffic jam, or in long queue; sample matter has been removed
- Revision history
- Index
Sample Access Line operation
During normal operation, the status of the Sample Access Line (SAL) is Online. Samples are
automatically routed to the SAL from input modules. The operator can transition the SAL status
to Offline or Online on the touchscreen user interface. Ensure that the track hoods are closed
and locked before operating the SAL.
NOTE: Before assay calibrations or quality controls are run on the Alinity ci-series reagent and
sample manager, the SAL must be placed Offline on one Alinity ci-series processing module that
is attached to the SAL. For multiple Alinity ci-series processing modules that are attached to the
SAL, refer to the Alinity ci-series Operations Manual to disable reagents to run assay calibrations
or quality controls while the SAL is Online.
CAUTION: Incorrect sample handling may cause a health risk due to incorrect analysis
results. Incorrect sample handling during laboratory automation system (LAS) operation
may cause sample contamination, which can cause delayed results or incorrect patient
diagnoses. Only allow trained personnel to operate the LAS. Specifically assess the
situation each time after an error occurs. Keep the track hood closed.
Related information...
Alinity ci-series SAL, page 39
Buttons, page 46
Start screen, page 47
Power on the Sample Access Line, page 48
Place the Sample Access Line online, page 49
Place the Sample Access Line offline, page 49
Pause the Sample Access Line, page 50
Deactivate pause mode, page 50
Restart the Sample Access Line, page 51
Main menu screen element descriptions, page 52
Login screen, page 52
Access the Login screen, page 53
Information screen element descriptions, page 54
Access the Information screen, page 55
Access the Configuration screen, page 55
Error message screen, page 55
Acknowledge an error message, page 56
Acknowledge a message, page 57
Buttons
The touchscreen user interface includes the following buttons.
Alinity ci-series SAL
Sample Access Line operation
Appendix A
46 Sample Access Line (SAL) Interface Manual